Overloaded Electrical System May Cause Fire

Recall Information

Manufacturer Weldon Division of Akron Brass
NHTSA ID 24E006000
Report Received Date 1/30/2024
Component N/A
Vehicles Affected 769
Completion Rate 2.6%
Recall Category Equipment
Rework Status Rework Gen 2
Software Recall Yes
OTA Update No

Description

Weldon Division of Akron Brass (Akron Brass) is recalling certain Hercules HC 1.7 Node multiplex nodes, part number 6060-2010-00. In the event of a short circuit or wiring failure, the firmware in the node may fail to shut off the output pin, resulting in overloaded electrical circuits.

Issue

Overloaded electrical circuits can overheat, increasing the risk of fire.

Consequence Summary

Overloaded electrical circuits can overheat, increasing the risk of fire.

Corrective Action

Weldon will update the firmware, free of charge. Owner notification letters were mailed February 08, 2024. Owners may contact Akron Brass customer service at 1-800-228-1161. Akron Brass number for this recall is TBS-24-002. This recall involves the same issue as stated in previous safety recall 23E-084. Vehicle owners may have vehicles that are affected by one or both recalls.

📋

Related to

Rework Generation 2

Related Recalls

More Information

https://www.nhtsa.gov/recalls?nhtsaId=24E006000

Envorso